Midi c, Xtended, Ontrol – Allen&Heath DP 1000 USER GUIDE User Manual

Page 65: Device parameter parameter id, Icon

Advertising
background image

icon

SERIES

AP3876 – Addendum to User Guide – Software Update V2.01

5

E

XTENDED

MIDI C

ONTROL

PARAMETER CONTROL Every console parameter is now mapped for independent MIDI
control. This is based on the NRPN system with the MSB selecting the channel number, and
the LSB selecting the parameter number in that channel (channel type specific).

Channel selection message:

0xBm, 0x63, <Channel>
(Controller 99)

Where <Channel> is

0x00 =

CH1 to 0x07 = CH8, 0x08 = FX1, 0x09 = FX2, and

0x40 =

GEQA, 0x41 = GEQB.

Parameter selection message:

0xBm, 0x62, <Param ID>
(Controller 98)

Where <Param ID> is shown below:

Parameter values are set using Data Entry MSB:

0xBm, 0x06, <Value>

All parameter values are ‘normalised’ from 0x00-0x7F

Device Parameter

Parameter ID

LF Gain

0x01

LF Frequency

0x02

LMF Gain

0x03

LMF Frequency

0x04

LMF Q

0x05

HMF Gain

0x06

HMF Frequency

0x07

HMF Q

0x08

HF Gain

0x09

HF Frequency

0x0A

PEQ

In/Out

0x0B

Drive

0x0C

Attack

0x0D

Release

0x0E

Knee

0x0F

Compressor

In/Out

0x10

Level

0x11

Attack

0x12

Decay

0x13

Gate

In/Out

0x14

Aux

Send Level

0x15

Foldback

Send Level

0x16

Trim

Level

0x17

Pan/Balance

Pan/Balance

0x18

FX1

Send Level

0x19

FX2

Send Level

0x1A

Fader Level

Level (transmit only, no recieve)

0x1B

Band Gain

0x00 Lowest Band 31Hz

0x09 Highest Band 16kHz

In/Out

0x20

GEQ

Linking

0x21

When linked, both GEQA&B messages (for
band gain & in/out) are generated by the I-CON

Advertising