Allen&Heath DP 1000 USER GUIDE User Manual

Page 66

Advertising
background image

6

AP3876 – Addendum to User Guide – Software Update V2.01

icon

SERIES

AUTOMATION

MIDI control is now extended to the

VENUE memory recalls as well as SONG. These use the

same program change messages as before but different banks. Refer also to the

icon User

Guide which details the original MIDI functions including

MUTE note on/off messages and

system exclusive data archive.

SONG RECALL

Program change in Bank 1
0xBm, 0x00, 0x00, 0xCm, pp
Where

m is

MIDI channel number

pp is

0x00 =

SONG 1

0x7E =

SONG 127

0x7F =

PAUSE

VENUE RECALL

Program change in Bank 2
0xBm, 0x00, 0x01, 0xCm, pp
Where

m is

MIDI channel number

pp is

0x00 =

VENUE 1

0x12 =

VENUE 19

G

LOBAL

F

UNCTIONS

The following global functions are controlled using MIDI system exclusive messages.

Where

MV is

major version number 0… 127

Mv is

minor version number 0… 127

m is

MIDI channel number

AMP MODE Changes mix source to amplifier channels A and B:

0xF0,0x00,0x00,0x1A,0x50,0x07,MV,Mv,0x0m,0x03,Mode,0xF7
Where

Mode is

0x00 for

L R

0x01 for

FB M

0x02 for

Aux FB

AUX PRE/POST Switches all channel aux sends either pre or post fader:

0xF0,0x00,0x00,0x1A,0x50,0x07,MV,Mv,0x0m, 0x05, Pre/Post,0xF7
Where

Pre is 0x00
Post is 0x7F

TRIM ON/OFF Enables or disables the channel level trim parameter:

0xF0,0x00,0x00,0x1A,0x50,0x07,MV,Mv,0x0m, 0x04, Off/On,0xF7
Where

Off is 0x00
On is 0x7F

Advertising