Remote control – zone level and source selection, Gr2 user guide, Voltage control – Allen&Heath GR2 PL-12 USER GUIDE 1 User Manual

Page 14: Configure remote control, Cat5 wiring, Level control, Source selection, Check the wiring before connecting power, 10v power, Source 1,2,3

Advertising
background image

14

GR2 User Guide

WARNING

THIS APPARATUS MUST BE EARTHED.

GR2

ZONE OUT

AUX

Z1

Z2

OUT

L

R

MUSIC IN

1

2

3
L

R

L

R

L

R

-

G +

Z1L

MIC 1

G

-

+

Z1R

-

G +

Z2

G

-

+

AUX

-

G +

MIC 3

G

-

+

MIC 4

-

G +

MIC 1

G

-

+

MIC 2

-

G +

MIC 5

G

-

+

MIC 6

-

G +

PAGE

G

-

+

MIC MIX

ZONE REMOTE

UTILITY REMOTE

EXPAND IN

( R - MUSIC 4 - L )

MADE IN THE UK BY ALLEN & HEATH LIMITED

ATTENTION: REMPLACER PAR UN FUSIBLE STRICTEMENT IDENTIQUE EN VALEURS.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

REPLACE FUSE WITH SAME TYPE AND RATING.

ALLEN&HEATH

WARNING

THIS APPARATUS MUST BE EARTHED.

GR2

ZONE OUT

AUX

Z1

Z2

OUT

L

R

MUSIC IN

1

2

3
L

R

L

R

L

R

-

G +

Z1L

MIC 1

G

-

+

Z1R

-

G +

Z2

G

-

+

AUX

-

G +

MIC 3

G

-

+

MIC 4

-

G +

MIC 1

G

-

+

MIC 2

-

G +

MIC 5

G

-

+

MIC 6

-

G +

PAGE

G

-

+

MIC MIX

EXPAND IN

( R - MUSIC 4 - L )

MADE IN THE UK BY ALLEN & HEATH LIMITED

ATTENTION: REMPLACER PAR UN FUSIBLE STRICTEMENT IDENTIQUE EN VALEURS.
FOR CONTINUED PROTECTION AGAINST RISK OF FIRE

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

REPLACE FUSE WITH SAME TYPE AND RATING.

ALLEN&HEATH

1

Z

1 S

OU

RC

E

2

+

10

V

3

Z

1 L

EV

EL

4

0V

5

Z

2 L

EV

EL

6

0V

7

Z

2 S

OU

RC

E

8

+

10

V

LEVEL

1

0V

off

2

3

4

+10Vref

SOURCE

4k7 ohm

linear

1k ohm

1k ohm

1k ohm

1k ohm

1k ohm

8V

6V

4V

2V

LEVEL

0V

4k7 ohm

linear

1k ohm

1k ohm

1k ohm

1k ohm

1k ohm

8V

6V

4V

2V

1

0V

2

3

+10Vref

SOURCE

1k ohm lin

1k ohm

1k ohm

1k ohm

1k ohm

1k ohm

6V

4V

2V

Source 1,2,3

1

off

2

3

4

SOURCE

1k ohm

2k2 ohm

zone 2

zone 1

+10Vref

LEVEL

4k7

lin

1k ohm

1k ohm

1k ohm

1k ohm

1k ohm

6V

4V

2V

Example 9

1

Z

1 S

OUR

CE

2

+

10

V

3

Z

1 L

EV

EL

4

0V

5

Z

2 L

EV

EL

6

0V

7

Z

2 S

OUR

CE

8

+

10

V

+10Vref

0V

2

3

SOURCE

1k ohm

1k ohm

1k ohm

1k ohm

1k ohm

6V

4V

Source 2,3

+10Vref

0V

Set min/max

1

2

3

SOURCE

LEVEL

0V

+10Vref

1k ohm lin

-20dB

2k2 ohm

Set min level

LEVEL

LEVEL

0V

+10Vref

4k7

lin

1k ohm

1k ohm

1k ohm

1k ohm

6V

4V

2V

Example 8

1

Z

1 S

OUR

CE

2

+

10

V

3

Z

1 L

EV

EL

4

0V

5

Z

2 L

EV

EL

6

0V

7

Z

2 S

OUR

CE

8

+

10

V

1

2

3

SOURCE

Zone 2 follow 1

source and level

Zone 2 follow 1

source only

LEVEL

0V

+10Vref

0V

+10Vref

4k7

linear

zone 1

zone 2

2

1

3 4 5 6 7 8

TIA/EIA 568A

WH

/G

N GN

WH

/O

R BL

WH

/B

L

OR

WH

/B

N BN

2

1

3 4 5 6 7 8

TIA/EIA 568B

WH/O

R OR

WH

/G

N BL

WH

/B

L

GN

WH

/B

N BN

Example 2

Example 3

Example 6

Example 5

Source OFF,1,2,3,4

Example 1

0V

Stepped level

LEVEL

Example 7

2

3

SOURCE

1k ohm

1k ohm

1k ohm

1k ohm

1k ohm

6V

4V

Push switches

+10Vref

0V

Example 4

1

2V

330 ohm

330 ohm

2k2 ohm

330 ohm

1

2

3

off

FUSE: T1AL

100 - 240V~

47-63Hz ~ 25W MAX

Remote Control – Zone Level and Source Selection

Voltage control

Level and source selection are voltage controlled

using an internal or external +10V DC reference voltage. This
means they can be controlled in many different ways including
custom wired potentiometers, switches and interface circuits, third

party controllers such as AMX or Crestron, or the Allen & Heath PL-
12 intelligent wall plate with PL-5 infra-red controller option.

LEVEL

0V=off +10V=maximum (0dB)

SOURCE

0V=off, +2V=1, +4V=2, +6V=3, +8V=4

Configure remote control

Set the front panel DIP switches M,

N, O, P to configure which zones and functions to control.

CAT5 wiring

The two zones are wired from one RJ45 socket,

convenient for daisy chaining two zone wall plates using a single
CAT5 cable run. Use standard CAT5 UTP or STP cable terminated
with an RJ45 plug at the GR2 and wired to the circuit at the wall

plate. Wire the circuit according to the RJ45 pin numbers shown
here. If you are using pre-installed cables, note that there are two
CAT5 connection standards, 568A and 568B. The cable colour code
differences are shown in the diagram. Check the pinout first.

Level control

Use a linear law rotary potentiometer or a switched

resistor ladder to control the zone level. Use a potentiometer or
ladder value between 2k and 10k ohms. We recommend 4k7 ohms.

Source selection

Use a resistor ladder wired to a rotary or other

type of switch. We recommend 5x 1k ohm resistors wired as shown
in the diagrams here. Wire the switch to the resistors according to

the combination of sources to be used, for example1234, 123, 234,
23. Switching to 0V provides an off position if required. Note that
you may wish to exclude music 1 from the source selection if it has
been configured as the priority source such as a jukebox.

Check the wiring before connecting power

Ensure

the CAT5 cable is correctly wired. Check the continuity of all wiring.
Ensure there are no shorts or exposed wire ends.

10V power

Do not draw more than 100mA from each

+10V pin. The internal 10V supply is protected against a short
circuit using a resettable fuse. If it trips, turn off the GR2, wait a few
seconds and turn it back on again.