Remote control – pl-12 wall plate, Gr2 user guide, Control – Allen&Heath GR2 PL-12 USER GUIDE 1 User Manual

Page 15: Cat5 cables, Zone selection, Setup menu options, Wired switch options, Pl-5 infra-red controller, Working with presets, Pl-12 setup options

Advertising
background image

GR2 User Guide

15

WARNING

THIS APPARATUS MUST BE EARTHED.

GR2

ZONE OUT

AUX

Z1

Z2

OUT

L

R

MUSIC IN

1

2

3
L

R

L

R

L

R

-

G +

Z1L

MIC 1

G

-

+

Z1R

-

G +

Z2

G

-

+

AUX

-

G +

MIC 3

G

-

+

MIC 4

-

G +

MIC 1

G

-

+

MIC 2

-

G +

MIC 5

G

-

+

MIC 6

-

G +

PAGE

G

-

+

MIC MIX

ZONE REMOTE

UTILITY REMOTE

EXPAND IN

( R - MUSIC 4 - L )

MADE IN THE UK BY ALLEN & HEATH LIMITED

ATTENTION: REMPLACER PAR UN FUSIBLE STRICTEMENT IDENTIQUE EN VALEURS.

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

REPLACE FUSE WITH SAME TYPE AND RATING.

ALLEN&HEATH

WARNING

THIS APPARATUS MUST BE EARTHED.

GR2

ZONE OUT

AUX

Z1

Z2

OUT

L

R

MUSIC IN

1

2

3
L

R

L

R

L

R

-

G +

Z1L

MIC 1

G

-

+

Z1R

-

G +

Z2

G

-

+

AUX

-

G +

MIC 3

G

-

+

MIC 4

-

G +

MIC 1

G

-

+

MIC 2

-

G +

MIC 5

G

-

+

MIC 6

-

G +

PAGE

G

-

+

MIC MIX

EXPAND IN

( R - MUSIC 4 - L )

MADE IN THE UK BY ALLEN & HEATH LIMITED

ATTENTION: REMPLACER PAR UN FUSIBLE STRICTEMENT IDENTIQUE EN VALEURS.

FOR CONTINUED PROTECTION AGAINST RISK OF FIRE

CAUTION: RISK OF ELECTRIC SHOCK. DO NOT OPEN. AVIS: RISQUE DE CHOC ELECTRIQUE - NE PAS OUVRIR.

REPLACE FUSE WITH SAME TYPE AND RATING.

ALLEN&HEATH

SOURCE

INDICATOR

LEVEL

LEVEL

INDICATOR

CONTROL

INFRA-RED

SENSOR

5

4

3

2

1

LEVEL

UP/DOWN

SOURCE
SELECT

SOURCE SELECT

MUSIC

MUTE

SOURCE OFF

PRESETS

5

4

3

2

1

PL-5

5

4

3

2

1

6

7

8

9

12

13

10

11

14

PL-12 WALL PLATE

PL-5 IR CONTROLLER

WALL PLATE DISABLE

Z2
Z1

Z2
Z1

WIRING OPTIONS

Z2 FOLLOW Z1

(ROOM COMBINING)

CAT5 CABLE

CAT5 CABLE

ITEM

SETUP

ITEM

SELECT

SETUP

OPTIONS

ENTER

SETUP

SOURCE

SELECT

SETUP MENU

FUSE: T1AL

100 - 240V~

47-63Hz ~ 25W MAX

Remote Control – PL-12 Wall Plate

The optional Allen & Heath PL-12 ‘intelligent’ wall plate provides

remote control of zone source selection and level. Full setup and
operating instructions are detailed in the PL-12 user guide. The
following provides an overview of its capability.

Control

A rotary level control provides 32 steps from fully off to

fully on. Up/down keys toggle through the available sources with

LEDs to indicate which source is active. An infra-red detector senses
the optional PL-5 hand held remote if it is used.

CAT5 cables

A standard CAT5/RJ45 cable connects between the

ZONE REMOTE port and the first PL-12 wall plate. Another cable
connects from the first wall plate to a second if both zones require

remote control. The control for both zones is passed down a single
CAT5 cable. This can be convenient for cable installation and for
situations where one remote is used to control both zones.

Zone selection

A jumper plug on the wall plate circuit card sets

which zone to control. Each zone can be controlled by one plate

only. However, you can set one plate to control both zones.

Setup menu options

The PL-12 presents the installer with many

setup options to satisfy the custom requirements of the application,
shown in the table here. These are accessed using setup mode.

Wired switch options

Two switch options are available at the

PL-12 wall plate. One switches operating mode for zone 2 control to
follow zone 1, convenient for room combining situations where a
divider screen is fitted with a switch to toggle mode. This switch
should be wired to the first wall plate. Another set of contacts can be
wired to a remote switch to disable the wall plate when it should not

be used by the operator.

PL-5 infra-red controller

The optional hand held controller may

be used with the IR detector on the PL-12 wall plate for wireless zone
level control and source selection. It provides additional functions
including direct source selection, a source mute switch and a preset
store/recall system.

Working with presets

The PL-5 hand held controller allows the

storing and recall of up to 4 presets of level, source selection and
zone 2 follow 1 setting. The installer can store these during
installation, then disable store to prevent them being overwritten by
the operator.

PL-12 setup options:

Zone 2 follow zone 1 = on, off
One PL-12 controls both zones

Sources to select = 1234, 123, 234, 23
Choose which sources can be selected

Source off = enabled, disabled
Allow a source off position

Power up = last settings, off, preset

Default settings when power is applied

Power up preset = 1, 2, 3, 4
Which preset to select if enabled above

Preset recall = enabled, disabled
Allows recall of presets using the PL-5

Preset store = enabled, disabled

Allows saving of presets using the PL-5

Follow mode = source only, source+level
What to control when in zone 2 follow zone 1
mode.

The PL-12 can be reset to factory default

(settings shown in bold above).