Step 1:

Choice of 1/2” diameter anchoring devices are at the discretion of the customer and not supplied by Anchor Indus-
tries.

Place anchoring devices as shown on the plan view below. (4) anchoring devices per base plate.

Note: For Your Convenience, (1) Template is supplied at the center of this manual.

Base Plate Layout

Base Plate
(Typ. 4)

Base Plate

(4) 3/4” dia. holes for 1/2”

dia. anchoring devices.

Dimensions are to center
points of base plates un-
less noted otherwise.

DIMENSION CHART

FOR BASE PLATE LAYOUT

Size

A

B

C

D

E

10’ x 10’

9’- 10”

9’-10”

10’-7”

10’-7”

13’-10 7/8”

10’ x 15’

14’- 10”

9’-10”

15’-7”

10’-7”

17 -9 9/16”

10’ x 20’

19’- 10”

9’-10”

20’-7”

10’-7”

22’-1 5/8”

15’ x 15’

14’- 10”

14’-10”

15’-7”

15’-7”

20’-11 3/4”

20’ x 20’

19’- 10”

19’-10”

20’-7”

20’-7”

28’-0 9/16”

20’ x 30’

29’- 10”

19’-10”

30’-7”

20’-7”

35’-9 7/8”

“C” Ref. dimension

“A”

“E” Diagonal

“D” Ref. dimension

“B”

Corner AA

Corner BB

Corner DD

Corner CC

Ridge

Frame shown in
dashed lines

Caution: Concrete installation
surface must be level.

3