Caution, Installation considerations, Component description – Bryant Energy/Heat Recovery Ventilator ERVBBSVA1100 User Manual

Page 2: Unit installation, Inspect equipment, Select location, Mount unit, Er v /hr v

Advertising
background image

2

The model operates at 2 airflows, 50 CFM in low speed and 100
CFM in high speed. This unit comes in two configurations, vertical

or horizontal. Special attention should be given to duct application,
balancing the ERV/HRV, and locating unit for easy access and

routine maintenance.

INSTALLATION CONSIDERATIONS

Inspect Equipment

Move carton to final installation location. Remove ERV/HRV from
carton taking care not to damage unit. Remove all packaging and

inspect unit for damage. Remove parts bag from inside unit. File
claim with shipping company if shipment is damaged or

incomplete. Check to make sure ERV/HRV unit matches Fig. 1 or

Fig. 2.

Select Location

The ERV/HRV should be located in a conditioned space and in

close proximity to a fused power source. It should be easily
accessible for routine maintenance.
If ERV/HRV is installed independent of a forced--air system, unit

should be located near the center of the air distribution system. If
ERV/HRV is installed in conjunction with a forced--air system, unit

should be located next to (or close to) the indoor equipment.

COMPONENT DESCRIPTION

The following listed items are components of ERVBBSHA (See

Fig. 4).

1. Exhaust--air connected to outdoor air exhaust hood.
2. Fresh--air intake connected to outdoor air inlet hood.
3. Fresh--air supply from ERV connected to return--air duct of

forced--air system.

4. Mechanical filters trap dust contained in the air.
5. Energy recovery core is a cross--flow type. The core trans-

fers heat between the 2 air streams.

6. Blowers bring in fresh--air from outside and exhaust stale--

air to outside.

7. Electronic control circuit ensures proper unit operation.
8. Stale air return from building connected to return--air duct

system.

ERV ports on side (bottom view)

3

2

8

1

4

4

5

6

7

A05263

Fig. 4 -- Conventional Horizontal Unit

See Fig. 5 for terminal connector block for wiring wall and timer
controls.

UNIT INSTALLATION

UNIT DAMAGE HAZARD
Failure to follow this caution may result in equipment

damage or improper operation.
Do not install ERV/HRV in a corrosive or contaminated

atmosphere.

CAUTION

!

Mount Unit

The ERV/HRV can be suspended from floor joists using chains and

4 springs. Attach metal hanging bracket to all 4 sides of cabinet.

(See Fig. 6.) The unit may be installed on a shelf if an isolation pad
is provided to dampen vibration. Unit should always be installed as

level as possible.

CONTROL

CONNECTOR

WALL CONTROL

YELLOW

RED

GREEN

BLACK

W ARNING

Ri s k of electric s hoc k. Be fo re per fo rmin g

an y maintenance or

s ervici ng, al wa ys

dis connect the unit fr

om it s p ow er s our ce .

A VER TI SS EMENT

Da nger d’électr ocution. Dé branchez

toujour s l’a ppareil av ant d’entre prendr e
de s tra vaux d’entretien ou de ré

paration.

CA UTIO N

Un s cr ew both s cr ew s to open the electrical

com par tment . To com plete ly remo ve , detac h

fr om it s retention wire in s ide.

AT TENTION

Dé viss er le s deux vi s p our ouvrir le com

par timent

électrique . P our retirer com plètement , le
détacher de s on fil de rétention intérieur

.

No light OFF or remote controled
Amber light LOW speed
Green ligh HIGH speed
Blinking light See User Manual
Sans lumière Arrêté ou contrôlé

par contrôle mura

l

Lumière ambre Basse vitesse
Lumière verte Haute vitesse
Clignotant Voir guide d’utilisation

Terminal
Connector

A

B

A07418

Fig. 5 -- Control Connector

ER

V

/HR

V

Advertising