Caution, Wall control, Connect ducts to erv/hrv – Bryant Energy/Heat Recovery Ventilator ERVBBSVA1100 User Manual

Page 4: Locate and install exterior hoods, Condensate drain, Types, Location

Advertising
background image

4

Connect Ducts to ERV/HRV

PROPERTY DAMAGE HAZARD
Failure to follow this caution may result in minor property

damage from sweating duct or loss of unit efficiency and

capacity.
If ERV/HRV duct work is installed in an unconditioned

space, insulated flexible duct is required.

CAUTION

!

Insulated flexible duct is required on both fresh--air inlet and

exhaust--air outlet ducts connecting to exterior wall. When

using insulated flexible duct, the vapor barrier of the flexible ducts
must be taped very tight to prevent condensation problems. To

reduce pressure drop, stretch the flex duct and support it in a proper
manner to avoid reduced airflow.
When connecting the ERV/HRV to a return--air duct system,

insulated flexible duct can be used. However, when metal or rigid
ducts are applied use approximately 18” (457mm) of flexible duct

at ERV/HRV ports for fresh--air supply, and stale--air return. When
using metal duct from fresh--air supply to system duct work, the

metal duct should be insulated. (See Fig. 8.) This can act as a
silencer when connecting ducts to return--air duct system. This

should eliminate transmission of noise or vibration from unit to

main duct system.

FRESH-AIR
SUPPLY

STALE-AIR
RETURN

FLEXIBLE DUCTS CONNECTING TO

RETURN-AIR DUCT SYSTEM

A08102

Fig. 8 -- Flexible Duct Fit--Up

Locate and Install Exterior Hoods

IMPORTANT: To prevent condensation problems, insulated
flexible ducts are required on both fresh--air inlet and exhaust--air
outlet ducts connecting between ERV/HRV and exterior wall.
Fresh--air intake and stale--air exhaust must be separated by at least
6 ft (1.8m). Fresh--air intake must be positioned at least 10 ft (3m)

from nearest dryer vent, furnace exhaust, driveway, gas meter, or
oil fill pipe. Fresh--air intake must be positioned as far as possible

from garbage containers and potential chemical fumes. When
possible, it is advised to locate the intake and exhaust hoods on

same side of house or building. The intake and exhaust hoods

should never be located on interior corners or in dead air pockets
(See Fig. 7). Both intake and exhaust hoods must be 18” (457mm)

from ground and at least 12” (305mm) above anticipated snow
level.
After selecting proper hood locations, make appropriate size hole

through exterior wall, pass flexible duct through hole and insert
hood tube into duct. Tape duct vapor barrier tightly around hood

tube and insert assembly back into wall and fasten securely.

Condensate Drain

(For ERV, skip this step and continue to the next step.)
To connect condensate drain, proceed as follows:

1. Punch out holes in foam insulation and door, then insert

sleeved grommets into bottom of unit using the gasket

washer and nut. (See Fig. 9.)

2. Cut two sections of plastic tubing, about 12” / 305mm long

and attach them to each drain.

3. Join the two short sections of plastic tubing to the “T” con-

nector and the main tube as shown.

4. Make a loop in the tubing below the “T” connector to create

a trap to prevent sewer gases from entering the ventilation
system. (See Fig. 9.)

5. Connect unit drain to building’s main drain. Provide slight

slope from unit for run--off.

A99268

Fig. 9 -- Condensate Drain With Loop Trap (HRV Only)

WALL CONTROL

Types

Four remote wall control options are available:

1. Basic Control (see Table 1).
2. OneTouch Control
3. Standard Control (includes dehumidistat)
4. Latent Control (includes humidistat for use with ERV’s only)

Table 1 – Basic Control

MODE

OPERATION

DAMPER

POSITION

FAN

SPEED

Off

Off

Closed to outside

Off

Low

Air exchange with

outside

Open to outside

Low

Intermittent

Air exchange with

outside

Open to outside

Low

High

Air exchange with

outside

Open to outside

High

Table 2 – Recommended Humidity Levels

OUTSIDE

TEMPERATURE

DOUBLE---PANE

WINDOWS

TRIPLE---PANE

WINDOWS

50°F / 10°C

55%

65%

32°F / 0°C

45%

55%

14°F / ---10°C

35%

45%

---4°F / ---20°C

30%

45%

---22°F / ---30°C

25%

35%

Location

The Standard Control and the Latent Control sense humidity and

not temperature. They must be located in an area where they will
continually monitor fresh air circulating within the home. Install

ERV/HRV wall controls as close as possible to main system

ER

V

/HR

V