pro Control High warning Set point

To adjust the high warning set point, press and release the wARN

button. The warning light will begin to flash and the pointer will move

to the previous high warning set point signifying that warning set

mode has been selected. Once in set mode, press the wARN button

to move the pointer down, or press the pEAK button to move the

pointer up. Three seconds after the last button press, the warning

light will stop blinking and the pointer will return to the current

reading. The warning set points are retained when power is removed

from the gauge.

pro Control High Over warn Set point

To adjust the high over warn set point, press and hold the wARN

button. After three seconds the warning light will begin to flash and the

pointer will move to the previous high over warning set point signifying

that over warn set mode has been selected. Release the warn button.

Once in set mode, press the wARN button to move the pointer down,

or press the pEAK button to move the pointer up. Three seconds after

the last button press, the warning light will stop blinking and the pointer

will return to the current reading. The over warn set points are retained

when power is removed from the gauge.

Change Backlight Color

To change the backlight color:

With power off, press and hold the warning button. Apply power to

the gauge. Release the wARN button. Press and release the pEAK

button. The pointer will move to half scale and the dial will illuminate with

the current Backlight Color. Press and hold the pEAK button to cycle

through the available colors. Once you have selected the desired color,

release pEAK and don’t press any buttons for about three seconds. The

dial will flicker white several times to indicate the desired setting has

been saved and the gauge will return to normal operation with your new

color selection. Color selections are saved when power is off.

power-Up

The pointer will move counter clockwise to the stop pin and then moves to the current gauge reading. This procedure is an auto-calibration function

and is performed on every power-up. While this test is being performed, the gauge may make a clicking sound. This is normal.

peak Recall

Press and hold the pEAK button to recall the highest temperature reading since the memory was last cleared. To clear the memory, press and hold

the pEAK button, and while still holding the pEAK button, press the wARN button. The pointer will move to the stop pin to indicate that the memory

has been cleared. Release the pEAK and wARN buttons to resume normal operation. The peak recall point is retained when power is removed

from the gauge.

full Dial warning

This gauge features full dial warning. When a warning point is reached, the entire dial illuminates in the programmed warning color. This feature is

available for both a high and low warning set point. In addition, the warning color will flash when an over warn point is reached.

pro Control Low Over warn Set point

To adjust the low over warn set point, press and hold the wARN

button, and while still holding the wARN button, immediately press and

hold the pEAK button. After three seconds the warning light will begin

to flash and the pointer will move to the previous low over warning set

point signifying that over warn set mode has been selected. Release

both buttons. Once in set mode, press the wARN button to move the

pointer down, or press the pEAK button to move the pointer up. Three

seconds after the last button press, the warning light will stop blinking

and the pointer will return to the current reading. The over warn set

points are retained when power is removed from the gauge.

pro Control Low warning Set point

To adjust the low warning set point, press and hold the wARN button,

and while still holding the wARN button, press and release the PEAK

button. The warning light will begin to flash and the pointer will move to

the previous low warning set point signifying that warning set mode has

been selected. Once in set mode, press the wARN button to move the

pointer down, or press the pEAK button to move the pointer up. Three

seconds after the last button press, the warning light will stop blinking

and the pointer will return to the current reading. The warning set points

are retained when power is removed from the gauge.

SET SCREW

1/8” NPT FITTING

A. pre-existing 1/8” NpT Threaded Hole

PROBE

SET SCREW

COLLAR

STAINLESS

CLAMP

middle 2/3

B. Stainless Clamp method