background image

Lighting mode

(Region B Color)
This gauge allows the dial lighting to operate in two modes, Full On or

Dimmable. Factory default is Full On.

full On: In this mode, the white lighting wire is ignored. The gauge

dial lighting is always on at full brightness. (unless you select NO color

when setting the Backlight Color). If using Full On mode, white wire

hook-up is not needed.

Dimmable: In this mode, the white wire is used to set the intensity of

the dial lighting from full brightness down to off.

To change the Lighting mode:

With power off, press and hold the pEAK button. Apply power to the

gauge. Release the pEAK button and the dial face will illuminate with

either white lighting or blue lighting. Press and release the PEAK button

to toggle between Full On (dial is illuminated white) and Dimmable (dial

is illuminated blue). Once you have selected the desired mode, don’t

press any buttons for about three seconds. The dial will flicker white

several times to indicate the desired setting has been saved and the

gauge will return to normal operation with your new mode selection.

Mode selections are saved when power is off.

NOTE: The Pro Control Active State does not

affect the color of each dial region.

Gauge Reset

It may be desired to reset the gauge. This clears programmable

settings to a system default. With power off, hold in both buttons.

Apply power to the gauge, wait two seconds, and release both buttons.

The dial face will flicker white several times and return to normal

operation. At this point, the gauge has been reset.
Reset Settings:
High Warning Set Point: Max Value

Low Warning Set Point: Lowest Value

Peak: Lowest Value

High Warning Color: Red

Low Warning Color: Green

Backlighting Color: White

Lighting Mode: Full On

High Warning Pro Control State: Active High

Low Warning Pro Control State: Active Low

High Over Warn Set Point: Max Value

Low Over Warn Set Point: Lowest Value

pro Control Active States

The active region for Pro Control outputs are user configurable. For

example, consider a pressure gauge with a low warning set point at

20 PSI . The gauge can be configured so the associated Pro Control

output is active when the pointer falls below the set point [less than 20

PSI] (active low) OR when the pointer is beyond the set point [greater

than 20 PSI] (active high). Likewise, consider a pressure gauge with

high warning set point at 95 PSI. Again, the gauge can be configured

so the associated Pro Control is active when the pointer falls below

the set point [less than 95 PSI] (active low) OR when the pointer

progresses beyond the set point [greater than 95 PSI] (active high).

To change the active state:

With power off, press and hold the pEAK button. Apply power to the

gauge. Release the pEAK button. Press and release the wARN

button. The gauge is now in Active State Set Mode. The pointer will

point straight up at the value in the top center of the dial. Press and

release the wARN button to toggle back and forth between the low and

high warning point active state modes. Doing so will cause the dial to

change back and forth between green and red. When setting the low

warning active state the dial face will be green. When setting the high

warning active state the dial face will be red.

Once the designated warning mode is selected (green or red) press and

hold the wARN button to toggle between active high and active low. As

you hold the button the pointer will continuously sweep from the left of

center and to the right of center pausing at each side. Left of center is

active low and right of center is active high. Release the wARN button

when the pointer is in the position of the desired active state. Once you

have selected the desired state, don’t press any buttons for about three

seconds. The dial will flicker white several times to indicate the desired

setting has been saved and the gauge will return to normal operation with

your new state selection. State selections are saved when power is off.

Change High warn Color

(Region C color)
warn Color Set mode:

With power off, press and hold the wARN button. Apply power to the

gauge. Release the wARN button. The pointer will be at the stop pin

and the dial illumination will be off. Press and release the wARN button

to cycle between HIGH warn color set and LOw warn color set modes.

In High warn color set mode, the pointer will move to full scale and the

dial will illuminate with the current High Warn color. In Low Warn color

set mode, the pointer moves to the minimum position and the dial will

illuminate with the current Low Warn color.
To change High warn Color:

When the High Warn color set mode has been selected (see above),

press and hold the wARN button to cycle through the available colors.

Once you have selected the desired color, release the wARN button.

Don’t press any buttons for about three seconds. The dial will flicker

white several times to indicate the desired setting has been saved and

the gauge will return to normal operation with your new High Warn color

selection. Color selections are saved when power is off.

Change Low warn Color

(Region A color)

warn Color Set mode:

With power off, press and hold the wARN button. Apply power to the

gauge. Release the wARN button. The pointer will be at the stop pin

and the dial illumination will be off. Press and release the wARN button

to cycle between HIGH warn color set and LOw warn color set modes.

In High Warn color set mode, the pointer will move to full scale and the

dial will illuminate with the current High Warn color. In Low Warn color

set mode, the pointer moves to the minimum position and the dial will

illuminate with the current Low Warn color.

To change Low warn Color:

When the Low Warn color set mode has been selected (see above),

press and HOLD the wARN button to cycle through the available colors.

Once you have selected the desired color, release the wARN button.

Don’t press any buttons for about three seconds. The dial will flicker

white several times to indicate the desired setting has been saved and

the gauge will return to normal operation with your new Low Warn color

selection. Color selections are saved when power is off.

Advertising
This manual is related to the following products: