Oil requirements, Oil capacity, Every day or 10 hours of operation – Autoquip SERIES 35 SCISSORS LIFT User Manual

Page 29: Every month or 100 hours of operation, Every year or 1000 hours of operation, Notice, 4 oil requirements, 5 oil capacity

Advertising
background image

29

6.2.4 Oil Requirements

Follow recommendations below that apply to your application.

Environment (Ambient Temperature)

Recommended Oil

Indoor locations with variable temperatures: 30 -
100 degrees F.

5W 30 or 5W 40 Multiviscosity Motor Oil

Indoor locations with constant temperatures: 60
- 80 degrees F.

SAE 20 Motor Oil

Outdoor locations: 30 - 120 degrees F.

5W 30 or 5W 40 Multiviscosity Motor Oil

Outdoor locations: 10 degrees F below 0 to 100
degrees F.

5W 20 or 5W 30 Multiviscosity Motor Oil

Cold Storage Warehouse: 10 - 40 degrees F.

Contact local Autoquip Service Rep.

Note: All oils are detergent type.

Note: Oil level should be 1" to 1-1/2" below the top of the reservoir.

6.2.5 Oil Capacity

Standard Series 35 Polyethylene Tank: Approximately 1.25 gal.

Series 35: 48S80 & 60Sxx Tube Tank: Approximately 2 gal.

Contractor polyethylene Tank: Approximately: 5.5 gal.

Vertical Steel Tank: Approximately: 10 gal.

Use approved fluids only. Use of unauthorized fluids may cause damage
to seals and hosing.


Do Not Use:

• Automatic Transmission Fluid (ATF)

• Hydraulic Jack Oil

• Brake Fluids








NOTICE

Advertising