24

SINGLE OVENS WITH SIDE MOUNTED CONTROLS

WHEN BUILDING YOUR FACADE, PROVISIONS MUST BE MADE FOR ACCESSING THE FOLLOWING:

(SEE SKETCH 15, PAGE 23)

FRONT:

LEFT SIDE:

REAR:

1.

Push-pull rods (2)

2.

Arched opening and lintel plate

3.

Combustion chamber door

1.

Hinged control access panel

2.

Side service access panel (optional). Access to this panel eases potential service access to the

valve, booster burner control, booster burner ignition module and thermostat, however all

components may be accessed though the side mounted hinged controls access panel.

1.

2.

Electrical connection

3.

Gas connection

4.

Minimum clearance for Service Technician and/or for safe operation

Rear booster burner, flame sensor and igniter - Provision should be considered for potential service

of these components. Following are 3 options:

A.

Rear access panel (recommended).

B.

Hinged or removable panel on the front of the facade to allow the removal of flue cover and

inserts. This provides greater access for a technician to service these components through

the front of the oven (see drawing below).

C.

Through the arched bake chamber entrance (difficult).

SEE INSTRUCTIONS ON PAGES 14-19.

VENTILATION, AIR SUPPLY AND FIRE PROTECTION:

BAKERS PRID