STARTUP

Saw Lubricant

The saw tank reservoir should be filled with 20 gallons of oil, or

approximately 1/4” from tank return edge. This ensures adequate

oil for the pump to run and keep the blade lubricated. The HP-30

saw is equipped with an oil delivery pump, which disperses the

oil directly onto the blade before going through the rock.

Periodically check the oil tank level after each day of use to en-

sure an adequate oil level of lubrication oil is in the tank. Expect

loss of cutting oil over time due to misting, absorption into the

rock material and heat evaporation.

PRE-START INSPECTION

The pre-start inspection should be performed before beginning any job.

HP30

STARTUP

Oil Level

(1/4" from return)

CAUTION

Check blade signs for core or segment cracks, uneven segment wear, pounding out of

round arbor hole, undercutting, segment loss, dishing or loss of tension. If the diamond

blade shows signs of any of these problems the blade must be replaced before starting

work. A damaged blade will not cut correctly and could cause physical injury.

2. Check Blade

Oil should always be about 1/4" from the return of the bottom of the blade. The pump should always be completely

covered. Do not overfill the reservoir tank!

1. Check Oil Level

Power Switch

The motor requires no special preparation or adjustment prior

to use of the slab saw. The on/off power control toggle switch is

located on the front of the saw. Pull the toggle switch away from

the saw to start the electric motor. Push the toggle switch toward

the saw to stop the electric motor.