Hp30 safety – Barranca Diamond HP30 Slab Saw User Manual

Page 8

Advertising
background image

8

This tool is intended for use on a circuit that has

an outlet that looks similar to the one shown in

Sketch B of Figure 2. The tool has a grounding

plug that looks similar to the plug illustrated in

Sketch A of Figure 2. Make sure the tool is con-

nected to an outlet having the same configuration

as the plug. No adapter is available or should be

used with this tool. If the tool must be reconnected

for use on a different type of electric circuit, the

reconnection should be made by qualified service

personnel; and after reconnection, the tool should

comply with all local codes and ordinances.

If permanently connected, this tool should be connected to a grounded metal permanent wiring system; or to a

system having an equipment-grounding conductor.

NOTE: Use of a temporary adapter is not permitted in Canada.

(A)

Figure 2

(B)

Use of under-sized extension cords result in low voltage to the motor that can result in motor burnout and

premature failure. Barranca Diamond warns that equipment returned to us showing signs of being run in a low

voltage condition, through the use of undersized extension cords, will be repaired or replaced totally at the

customer's expense. There will be no warranty claim.

To choose the proper extension cord,

• Locate the length of extension cord needed in table below.

* Once the proper length is found, move down the column to obtain the correct AWG size required for that

length of extension cord.

WARNING

HP30

SAFETY

EXTENSION CORD LENGTH

Nameplate

Amperes

115V

25'

50'

75'

100'

150'

200'

250V

50'

100'

150'

200'

300'

400'

0 - 5

16

16

16

14

12

12

5.1 - 8

16

16

14

12

10

8.1 - 12

14

14

12

10

12.1 - 15

12

12

10

10

15.1 - 20

10

10

10

Advertising