BKI ALF-FC Automatic Lift Fryer User Manual

Page 15

Advertising
background image

Automatic Lift Fryer

Operation

13

Item #

Description

Function

6

ALARM button

This button allows the user to set an elapsed time at which the
internal alarm will sound during a cycle. The time is set by
pressing and holding the ALARM button while using the UP and
DOWN arrows to change the time. The controller will limit the
alarm time to be less than the currently programmed interval cycle
time. The default alarm time is 0:00 which disables it. The ALARM
time is saved on power down in the same manner as the last
interval time. When a time cycle is running and the alarm time has
elapsed the internal alarm will sound for 10 seconds. For
example, a cycle time 10:00 and alarm time of 2:00 would cause
the alarm to sound for 10 seconds once the controller has counted
down from 10:00 to 8:00. This button is also used to cancel the
STIR OIL function.

A, B, C, D preset
buttons

These buttons are used to save and recall preset cycle and alarm
times, saving operator time and minimizing error when changing
interval cycle times and alarm times. To save the current interval
and alarm times into one of the preset locations, press and hold
the A, B, C, or D preset button for 2 seconds and the controller will
double chirp to indicate the times have been saved. To recall any
preset time, press and quickly release the appropriate button and
the time values are loaded and displayed.

Beeper

A beeper sounds when the timer counts down to 0. Pressing the
START/STOP button stops the beeper and resets the timer
causing the display to return to the original starting time. At this
point, time can be changed using the TIME SELECT buttons or
the preset buttons. The beeper will also sound for 10 seconds if
the alarm time has elapsed during a timing cycle. When the STIR
OIL function begins the beeper will sound until the ALARM or
START/STOP button is pressed.

Display

Used to display the time. It also displays the words “STIR” then
“OIL” in .5 second intervals until the ALARM or START/STOP
button is pressed.

7

High Limit Reset

Switch

Located under the control panel. If the heating elements inside the
pot reach an unsafe temperature, power is automatically removed
from the control panel and elements. Pressing this switch returns
power to the control panel and elements.

8

Drain Lever

DRAIN OPEN – When placed in this position, the drain valve
opens and shortening in the pot drains into the vat. Also power is
removed from the control panel and elements.

DRAIN CLOSED – When placed in this position, the drain valve is
closed to prevent shortening from draining from the pot.

9

Fill Lever

FILL THRU POT – When placed in this position, shortening can
be pumped automatically from the vat to the pot if the rocker
switch is in the FILTER position.

FILL THRU HOSE – When placed in this position, shortening can
be pumped from the vat to the pot via a connected hose if the
rocker switch is in the FILTER position.

10

Rinse Hose Connector

Used to connect the Rinse hose for cleaning and refilling the pot.

11 Pump

Motor

Reset

Switch

If the motor overheats while filtering, it will automatically shut off.
Wait 15 minutes to allow motor to cool before pressing this switch.

Advertising
This manual is related to the following products: