BKI ALF-FC Automatic Lift Fryer User Manual

Page 21

Advertising
background image

Automatic Lift Fryer

Operation

19

Table 2. Product Programming Procedure

STEP ACTION

DISPLAY

COMMENTS

1 Press

the

FILTER/OFF/FRY

switch to FRY.

LOW

2

Press PROG on the keypad.

PROGRAM CODE

3

Input 1724 and press ENTER.

PROGRAM PRODUCT #

4

Select the program product

number (1-8).

PROGRAM PRODUCT X X refers to the program

number you selected.

5

Press ENTER.

PROGRAM TIME1

00:00

This command allows you
to specify the cooking time
for this stage. The time
displayed may be a
previously programmed
value.

6

Press TOGGLE/CLEAR and

input the number of minutes you
want to cook.

PROGRAM TIME1

XX:XX

XX:XX refers to the
number of minutes you
input.

7

Press ENTER.

PROGRAM TEMP1

000

F

This command allows you
to specify the cooking
temperature for this stage.
The temperature displayed
may be a previously
programmed temperature.
The temperature scale
may also display

C

depending on the system
option that is set.

8

Press TOGGLE/CLEAR and

input the cooking temperature for
product to be cooked.

PROGRAM TEMP1

XXX

F

XXX refers to the cooking
temperature you input.

9

Press ENTER.

PROGRAM TEMPCOM1

FLEX TIME

This command enables
you to select whether or
not time is allowed for the
fryer to recover from
temperature loss while
cooking during this stage.
The FLEX TIME option will
allow the fryer to recover
from temperature loss.

10

Press TOGGLE/CLEAR until the

desired option is displayed.

PROGRAM TEMPCOM1

X

X refers to the
temperature compensation
option selected.

11

Press ENTER.

PROGRAM VALVE1

CLOSED

This command allows you
to specify whether the
solenoid valve will be open
or closed during this
stage.

Advertising
This manual is related to the following products: