Gently insert the element into the location hole until it reaches the approximate depth of the front
face insulation. (See photo 2) This should require no force at all. Then with a slight twisting action
locate the front end of the element in the front face location hole and gently insert element as far as
possible.(See photo’s 3 & 4) Again no force is required. There should be approximately 6-8 mm
between the elements porcelain terminal connector and the rear insulation.













Repeat the above procedure for the other two elements.

The braids should then be connected as follows. Starting from one side. Take the loose end of
braid that is connected to the connection block (See Photo 5) and attach to the first element tail of
the nearest element using M6 screw, washer, nut (See Photo 6).













Connect the second element tail of the same element to the first element tail of the centre element
using the same method with the loose braids provided (See Photo 7). Repeat this process on the
opposite side.













Once the braids are all connected and the fixings secured, carefully tidy the braids and ensure they
are not touching each other or any other component (See Photo 8).

Photo 3

Photo 4

Photo 5

Photo 6

Photo 7

Photo 8