Bunn TB3Q User Manual

Page 9

Advertising
background image

Page 9

AUTO SWEETENER SET-UP

CAUTION - The brewer must be disconnected from the power source throughout the Initial Set-Up, except

when specified in the instructions.

1.

Remove the top lid and both rear panels.

2.

Make sure the brewer water supply is off.

3.

Connect sweetener hose from the bag in a box delivery system to the rear fitting marked "Sweetener" .

IMPORTANT - System delivery pressure must be regulated between 30-40 psi. System also needs to deliver

product for at least 4 minutes without shutting off. Some pump systems shut off after a few minutes of con-

tinuous running.

(TB3Q/TB3Q-LP ONLY)

4.

Plug brewer into the power source.

5.

Place an empty reservoir under the dilution nozzle of the brewer.

6.

Close the adjustment valve on the rear of the brewer fully (clockwise), then open (counterclockwise)

1/2 turn.

7.

Set the selector switch to the "Sweetened" side and press the "Start" switch momentarily. (The sweet-

ener will come out immediately.)

8.

Run sweetener for 1 minute, then set selector switch to the "Off" position. The flow will stop.

9.

Measure the amount of sweetener dispensed and calculate if the volume needs to be increased or

decreased (Dilution cycle is usually between 3 to 3 1/2 minutes).

10.

If adjustment is needed, turning the adjustment valve clockwise decreases the amount of sweetener

dispensed and turning the adjustment valve counterclockwise increases the amount of sweetener dispensed.

11.

After the desired volume has been set, turn the water supply on.

12.

Reinstall the top lid and rear panels. The brewer may now be returned to service.

(TB3/TB3-LP ONLY)

4. Set the "Delay knob on the dilution timer to the 3 minute setting. (The minimum delay setting)

5. Plug brewer into the power source.

6. Place an empty reservoir under the dilution nozzle of the brewer.

7. Close the adjustment valve on the rear of the brewer fully (clockwise), then open (counterclockwise) 1/2

turn.

8. Set the selector switch to the "Sweetened" side and press the "Start" switch momentarily. (After approximately

3 minutes the sweetener will come out of the dilution nozzle.)

9. Run sweetener for 1 minute, then set selector switch to the "Off" position. The flow will stop.

10. Measure the amount of sweetener dispensed and calculate if the volume needs to be increased or decreased

(Dilution cycle is usually between 3 to 3 1/2 minutes).

11. If adjustment is needed, turning the adjustment valve clockwise decreases the amount of sweetener dis-

pensed and turning the adjustment valve counterclockwise increases the amount of sweetener dispensed.

12. Set the "Delay" knob on the dilution timer back to the 6 to 7 minute setting.

13. After the desired volume has been set, turn the water supply on.

14. Reinstall the top lid and rear panel. The brewer may now be returned to service.

41465 082208

Advertising
This manual is related to the following products: