Model 99FRD, 100CRD & 102CRD oil burners — Instruction manual

Carlin part number MN99102 Rev. 10/21/10

– 6 –

Figure 1 99FRD, 100CRD and 102CRD Minimum combustion chamber dimensions (all dimensions in inches)

2. Prepare site • assemble burner • mount burner

(continued)

Chamber confi gurations
A Chamber with water-backed fl oor and target wall, with refractory linings on

fl oor and target wall.

B Chamber with water-backed fl oor and target wall, with refractory lining on

target wall only.

C Chamber with water-backed fl oor and target wall, without refractory linings.

D Refractory chamber, no water-backed surfaces (dry base design).

E Chamber with refractory fl oor and water-backed target wall (without target

refractory lining).

F

Chamber with refractory fl oor and water-backed target wall (with target refrac-
tory lining).

Notes for dimension table
1 Some tested appliances operate well with dimensions other than shown

below.

2. Generally, applications should be acceptable with dimensions larger than

listed.

3. Horizontal cylinder chambers should have a diameter at least as larger as the

minimum width listed. For steel cylinder chambers, increase this dimension
by from 1 to 4 inches.

4. Wing walls are not recommended. Corbels can be benefi cial to heat distribution

in some applications.

5. DV is the minimum diameter for vertical cylindrical chambers (refractory or

refractory-lined chambers only).