Controller programming – Carter-Hoffmann VCNH3W2S-CVR User Manual

Page 8

Advertising
background image

8

CONTROLLER PROGRAMMING

(Continued)

To enter into program
mode, display must be in
operating mode and not
in a timing cycle.


NOTE:
Each module can
be programmed individual-

TIMER
(Program Mode)

TIMER range:
1 minute to 9 hours, 59 min.

NOTE: Timers cannot be
programmed for less than 1
minute.

PROGRAM TIMER (P1 through P6)

1. Press and hold TIME KEY

until digital readout flashes.

2. Press INCREASE KEY

*

to add time. Each time key is

pressed, timer is increased by 1 minute. Hold key to scroll faster.

3. Press DECREASE KEY

*

to subtract time. Each time key is

pressed, timer is decreased by 1 minute. Hold key to scroll faster.

4. Press TIME KEY

to save changes and return to P1.

5. To program timers P2 through P6:

A. Press INCREASE KEY or

DECREASE KEY

to select the desired program.

B. Repeat steps 1 through 4 above for each program

TO CANCEL TIMER: Press and hold TIME KEY

for 2 seconds.

NOTE: If no key is pressed for 5 seconds, display returns to “P 1”.
Changes will be saved.

Timer Keys

Temperature

Key

Digital Readout

(one for each key)

On/Off

Toggle Switch

*

Increase/Decrease Keys

top for timers 1,2,3; bottom for timers 4,5,6

CHANGING TEMPERATURE SCALE

1. Press the temperature button until the display starts flashing.

Then, press both the INCREASE and DECREASE KEYS at the
same time until

°F is displayed.

2. Press the INCREASE KEY or DECREASE key to toggle between

°F and °C.

3. Once desired scale is selected, press the TEMPERATURE KEY

to save and exit.


Note: If F is not displayed after pressing both the INCREASE and DE-
CREASE KEYS, then the controller does not have the proper soft-
ware. Contact Carter-Hoffmann Technical Service for a replacement
controller.

Advertising