Carter-Hoffmann CW4 User Manual

Page 14

Advertising
background image

14

TROUBLESHOOTING GUIDE

SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

No power to unit

Not plugged in or circuit breaker tripped

Check or reset circuit breaker
Connect to proper receptacle

Power cord damaged

Check - replace if required

Power switch damaged or defective

Check - replace if required

Product dries out too
quickly

Operation where product temp is too high

Check product temps going into holding
cabinet

Thermostat incorrectly set or defective

Check proper operation or calibration of
thermostat

Unit is on, motors are
running but no heat

Internal wiring error

Call service technician

Element hi-limit trip / defective

Call service technician

Takes too long to get
to temperature

Improper voltage

Call service technician to verify in-
coming voltage matches cabinet specifi-
cations.

Unit is hot
but low or no airflow

Internal wiring error

Call service technician

Circulation motor has quit

Call service technician

Improper voltage

Call service technician to verify in-
coming voltage matches cabinet specifi-
cations.


NOTE:


The technical content of this manual,
including any wiring diagrams, schemat-
ics, parts breakdown illustrations and /
or adjustment procedures, is intended
for use ONLY by qualified technical
personnel

.


NOTE:

For warranty service, call Carter-Hoffmann
direct at 800-323-9793 for authorization,
we will dispatch the nearest authorized
service agency.