NORMAL OPERATION (CONT.)

CAUTION:
HOT SURFACE


Inner surfaces of the unit
will be very hot during and
after operation.

Avoid touching the cabinet
when loading or removing
product.

RELATIVE HUMIDITY LEVELS FOR DIAL SETTINGS



Operating ranges:
- air temp: 85ºF-200ºF
- humidity: OFF-90%

CAUTION:
STEAM HAZARD

This unit produces steam,
use caution when cleaning
or opening the doors.

CAUTION:
WATER HAZARD

A water trough is located at
the base of the door to col-
lect condensation. Make
sure to periodically check
and empty it regularly to
avoid overflow. The trough
can be removed and emp-
tied by simply sliding it off
the bolts at the base of the
door.

Humidity Setting

Temperature

Setting

Low Medium High

100°F to 130°F

Yellow Zone

L = 30%

Yellow Zone

M = 60%

Yellow Zone

H = 90%

130°F to 160°F

Orange Zone

L = 30%

Orange Zone

M = 60%

Orange Zone

H = 90%

160°F to 200°F

Red Zone

L = 30%

Red Zone

M = 60%

Red Zone

H = 90%

Proofing

Set at Lowest

Temp in White

Zone

N/A N/A

Yellow Zone

H = 90%

The chart below indicates the settings for temperature and humidity.
The key is to match the Low (L), Medium (M) and High (H) relative
humidity levels in each color band on the humidity dial with the cor-
responding color band at your desired temperature setting.

Example: For 150°F and 30% RH, set dials as indicated by the
green arrows.