HOLDING CABINET—NORMAL OPERATION

CAUTION:
HOT SURFACE

Inner surfaces of the unit
will be very hot during and
after operation.

Avoid touching the cabinet
when loading or removing
product.

FIRST USE

Turn the cabinet on using the power switch located on the far left
side of the control panel. Once the switch is turned on, the control
display will illuminate.

When the cabinet is first turned on, the temperature display will show
the current hardware / software revision, for example: “r26”. Then
display will then alternately flash “PrE” and the set point values.

To adjust the temperature setting, rotate the TEMP dial to the de-
sired set point and stop. After 3 seconds, if setting is adjusted, the
newly adjusted value will be stored in the controller’s memory. If the
cabinet power is interrupted, the last value set will be the new value
restored upon power being restored.

It will take approximately 30 minutes for the cabinet to warm up to a
factory default setting of 160º F. Once the set point is reached, a
short alarm burst will be heard to indicate that the cabinet has
reached the set point.


Factory default setpoints:
- temperature: 160ºF
- low temp alarm: 140ºF

Operating ranges:
- temp alarm: 80ºF-180ºF
- air temp: 90ºF-200ºF


The factory default for the
temperature display is in ºF.

To change the display to
read in ºC, push in and hold
the view actual button for 10
seconds. The display will
now read in ºC.

To change the display temp
back to ºF, repeat the same
procedure above.

hot

LOGIX

NOTE: The holding cabinet section of this appliance
and drawer warmers can be operated independently of
one another. See pages 9-11 for operation instructions
for the drawer warmers.