Display codes and definitions, Start-up operation verification error 1 2 4 3 – CHAMPION DH5000 Single Source Gas Door Machine Manual User Manual

Page 86

Advertising
background image

78

Display Codes and Definitions

Temperature Display Adjustment - (For Service Technicians Only)

The illustrations below show the codes that may appear on the temperature displays.

START-UP

OPERATION

VERIFICATION

ERROR

1

2

4

3

E

E flashes and bar is blank.
1. Verification operation is complete

for the display.
Press the RESET button

on the display board to exit mode.

C A L

CAL displayed and bar is blank:
1. Display is in the verification

mode.
Press the RESET button

on the display board to exit mode.

E E E

EEE displayed and bar is blank:
1. Display is in the verification

mode but the thermister

was not unplugged

prior to verification.

1 6 0

160 displayed and bar is blank:
1. Display verification in process.
The meter should flash “E”

when the TEST button

is released.

Numbers and bar are blank:
1. Main power or dishwasher OFF.
2. Tank temp. below 70°F/21°C.
Turn power OFF, then ON to check

display segments.

E

E displayed and bar is blank:
1. Thermister is open or shorted.
Troubleshoot the thermister

circuit connected to the display.

Number and bar LEDs cycle:
1. This is the Display segment test

when the dishwasher power

is turned ON.
Check for defective LED

segments during the test.

H H H

HHH displayed and entire the bar is lit:
1. The temperature in the tank has

exceeded 210°F/99°C.
Reset the hi-limit thermostat, then

adjust or replace the temperature

control thermostat.

2

1 5

ALL Digital Displays
Numbers indicate between 70-209°F

or 21-99°C; and the bar is illuminated

left-to-right, from yellow to green:
1. Normal display operation.
2. Displaying temperature.

NOTE:

The final rinse display may indicate a temperature

less than a minimum of 180

°

F/82

°

C during

the wash cycle. This is normal, but during the

final rinse cycle (when the pressure gauge indicates

a flowing pressure of 20-22 PSI), the final rinse

temperature display will read between

180-195

°

F/82-91

°

C.