Model dh5000 condensate removal option description – CHAMPION DH5000 Single Source Gas Door Machine Manual User Manual

Page 99

Advertising
background image

91

P/N 114958 - Condensate Removal Option Installation Instructions

Model DH5000 Condensate Removal Option Description

81 38

[1901]

"

60 18

[1526]

Machine

Height

Condensate

Removal

Mounted

"

25

[635]

"

~

~

Condensate

Removal

Shroud

A

Machine

Mounted

Condensate

Removal

Control Box

C

B

The condensate removal option is a stainless steel vent shroud (approx. weight 60 lbs./27 kg)

and a control box mounted on the left side of the dishwasher.

1. The condensate removal shroud

is mounted on the top rear of the

dishwasher using (4) 1/4-20 x 1/2" SST

truss head screws. (See Figure A).

2. The shroud must be installed before the

dishwasher is permanently placed and

before connecting the utilities.

3. The dishwasher should be positioned in

a manner whcih allows the dish tables

and the machine to align for the proper

loading and unloading of the dish racks.

(See Figure B).

4. Only a 3/4" NPT cold water supply

is required for the Condensate

Removal Option

(See Figure B).

! ATTENTION !

The condensate removal shroud must be installed before the dishwasher is permanently placed

and before the utilities are connected.

! VERY IMPORTANT !

The incoming cold water supply pressure

must be a minimum

of 45 PSI flowing pressure measured

at the dishwasher inlet connection.

Advertising