1. Electrical connections for a direct vent

fan (supplied by others) are made in the

Direct Vent Control box, (See Figure B

at right), which was shipped with the

dishwasher and stowed in the rear of

the machine.

2. The control box can be mounted on the

left-side of the machine (See page 81,

Figures I & J) or wall-mounted using

P/N 900958, Model DH5000 Control

Box Wall Mount Kit. The wall-mount kit

is sold separately.

P/N 114959 - Direct Vent Option Installation Instructions

Electrical Connections for a Direct Vent Fan (Supplied By Others)

! IMPORTANT !

Electrical installation must be performed by qualified personnel in accordance with all local codes

and regulations or in the absence of local codes then in accordance with the National Electrical

Code or the Canadian Electrical Code.

DO NOT CONNECT POWER UNTIL THE FAN IS COMPLETELY INSTALLED.

B

Water-tight

Direct Vent

Option

Control Box

Fittings and cables for

an external power supply

and output

to the direct vent

fan must be supplied

by the installer.

Factory

Prewired

Cable

Direct Vent Control Box:

Cable Connections:

1. Refer to Figure B at right.
2. Remove the control box water-tight cover.
3. An interconnect control cable between

the dishwasher and the control box is

prewired at the factory.

DO NOT CUT NOR DISCONNECT

THIS CABLE WITHOUT PERMISSION

FROM THE FACTORY.

4. One cable is required to bring power

from an external power source into

the control box.

DO NOT USE THE DISHWASHER

AS A POWER SOURCE FOR A DIRECT

VENT FAN SUPPLIED BY OTHERS.

5. One cable is required to connect

power from the control box to the

direct vent fan.