2 installing cover on pipe, Installing cover on pipe -9, Figure 7 – CiDRA Elevated Temperature Sensor Head User Manual

Page 13: Pre-amplifier mounting screws -9, Figure 8, Remove fiberglass insulation -9, Figure 9, Sensor cable feed-through assembly -9

Advertising
background image

2.4.2

Installing Cover on Pipe

Remove the pre-amplifier housing cover from the upper cover
assembly. Disconnect external connector cable assembly from pre-
amplifier assembly. Remove the four screws holding the pre-amplifier
assembly in place. Remove the pre-amplifier and place it in a secure
location so it will not be damaged.

Pre-amplifier
mounting screw(s)
(lower screw
removed)

Figure 7

Figure 8

Figure 9

Pre-amplifier Mounting Screws

Carefully remove the fiberglass insulation from the pre-amplifier
housing by grasping it along the edge and pull it upward. Place it in a
secure location to keep it from being damaged.

Remove Fiberglass Insulation

Remove the sensor cable feed-through from the pre-amplifier housing

Sensor Cable Feed-Through Assembly

21020-01 Rev 01

Page 2-9

Advertising