2 sensor head installation, 1 caution: high temperatures, 2 tools required for installation – CiDRA Elevated Temperature Sensor Head User Manual

Page 6: Sensor materials, Sensor tools/supplies, Cover materials, Sensor head installation -2, Caution: high temperatures -2, Tools required for installation -2, Sensor head installation

Advertising
background image

2

SENSOR HEAD INSTALLATION

2.1

Caution: High Temperatures

Be careful when installing or removing the high temperature system.
Incidental contact with the process pipe may cause serious burns.
The sensor cover and fasteners may become extremely hot.

Always use appropriate gloves and clothing.

WARNING

Potential burn hazard. Always wear appropriate gloves when
installing or removing system from hot pipes.

2.2

Tools Required For Installation

Refer to the VF-100 Installation Manual for a list of tools required for
installation. Additional tools and supplies are listed below

Sensor Materials

Sensor Tools/Supplies

0.005” thi

ck polyimide sheet

9/32” socket or slotted screwdriver
adapter for use with torque wrench

Sensor alignment sheet

Torque wrench with 22 in-lb capacity

f

Alignment sheet attachment springs

2 ea ¼” x 20’ roll of 100% expanded
Value Seal Joint Sealant

8 sensors

Cover Materials

Tefzel

®

cable tie

Cover Assembly

Wire number tags

Preamplifier Assembly

Senso

r alignment sheet springs

Cover Fastener Kit

Table 1

Materials & Tools For Elevated Temperature Sensor Head Installation

21020-01 Rev 01

Page 2-2

Advertising