Figure 10, Cover lower support ring -10 – CiDRA Elevated Temperature Sensor Head User Manual

Page 14

Advertising
background image

For horizontal pipe installations, install the cover half with the
preamplifier box over the sensor band such that it is centered on the
band and over the sensor band cables (allows for maximum sensor
cable length). Ensure the cables are accessible.

Install the lower cover half and temporarily clamp the upper and lower
cover halves in place using spring clamps (or equivalent). Important:
Do not allow the cover end seals to touch any part of the sensor array
including the polyamide insulation. The seals (and seal rings to be
installed in the following steps) should only be in contact with the
process pipe.

For vertical pipe installations hang the cover halves from the cover
support ring. Temporarily install the cover lower support ring on the
bottom of the cover assembly.

Figure 10

Cover Lower Support Ring

Install the lower cover half and temporarily clamp the upper and lower
cover halves in place using spring clamps (or equivalent). Important:
Do not allow the cover end seals to touch any part of the sensor array
including the polyamide insulation. The seals (and seal rings to be
installed in the following steps) should only be in contact with the
process pipe.

21020-01 Rev 01

Page 2-10