6.2 - AUTOMATIC GAUGES CALIBRATION

6.2.1 - RIM DISTANCE GAUGE

Leave the distance gauge in rest position

and

press

Pull out the gauge up to the adapter fl ange

and

press

C

ORRECT CALIBRATION

Return the gauge to rest position.

The wheel balancer is ready for operation.

NOTE.: In the event of errors or faulty operation, the writing

r.P.:

ap

pears on the display : shift the

gauge to the rest position and repeat the calibration operation exactly as described above. If the

error persists, contact the Technical Service Department. In the event of incorrect input in the rim

distance gauge calibration function, press

to cancel it.

6.2.2 - DIAMETER GAUGE

E40 m

m

Plac

e the round part of the gauge terminal on the fl ange as shown in the fi gure

and

press

The number 8 ± 3° appears on the left display .

Turn the gauge downward position the


round part of the gauge terminal at 40 mm
(radial distance) from the fl ange as indicated
in

the

fi gure; alternatively use one of the cones

provided as shown in the images

The nu

mber 289 ± 3° should appear on the left display. The calibration is already correct.

If not, press the

button holding the gauge still at 40 mm: the number 289

appears on the left display.

Return the gauge to rest position.