6.3 - BALANCING MACHINE CALIBRATION

To calibrate the machine, operate as follows:

Fit a medium-sized wheel with steel rim on the shaft. Example: 6” x 15” (± 1”) best with less then 20 g unbalance

Take the exact measurements of the wheel mounted as described in

DATA SETTING

.

P

RESETTING

OF

INCORRECT

DIMENSIONS

WOULD

MEAN

THAT

THE

MACHINE

IS

NOT

CORRECTLY

CALIBRATED

,

THEREFORE

ALL

SUBSEQUENT

MEASUREMENTS

WILL

BE

INCORRECT

UNTIL

A

NEW

SELF

-

CALIBRATION

IS

PERFORMED

WITH

THE

CORRECT

DIMENSIONS

!

Perform a manual spin under normal conditions

Add a sample weight on the outside in any angular position.


Sample weight:

60 g. (2.00 .oz) for car

300 g. (10.0 .oz) for truck

Perform a manual spin

Shift the sample weight from the outside to the inside keeping the same angu


lar

position.

Perform a manual spin

Turn the wheel until the sample weight is in the 12 o’clock position

END OF CALIBRATION

CANCELS CALIBRATION IN ANY PHASE.