Video balancer – COATS Series XR 1750, 1750-2D, 1750-3D, 1750-3DI Balancer User Manual

Page 29

Advertising
background image

Important: Always read and follow the on-screen operating instructions.

• 23

Video Balancer

Service Adjustments

Press the

key and select the SERVICE

ADJUSTMENTS option

for the following menu

selections.

Important: These service adjustments are password

protected. Contact your factory trained COATS

®

Service Technician before attempting any upgrade or
repair that may affect the machine dimension meas-
urement system.

Figure 38 - Service Adjustments Screen

Distance Arm Calibration - calibrates the dis-

tance part of the offset arm.

Width Sonar Calibration - calibrates the

width using a sensor.

Diameter Arm Calibration - calibrates the

diameter part of the offset arm.

Distance/Diameter Arm Type - Toggle to

METAL or PLASTIC. Set to match the style/type of
arm installed on the balancer.

Temperature - the ambient temperature set-

ting for sonar.

Recommended setting is 70˚ F.

Note: Calibrate the offset arm first, since it is very

important that the wheel dimensions are correct.

Distance Arm Calibration - Follow these instructions

on-screen when calibrating the DISTANCE ARM option

:

1. Move offset arm to position 0 on gauge, hold at

location and press NEXT option

.

2. Move offset arm to position 6" (not 0.6") on gauge,

hold at location and press NEXT option

.

Note: Position the gauge as shown in figure 39.

Figure 39 - Distance Arm Calibration

3. Return offset arm to home position.

4. Calibration Accepted.

5. Press NEXT option

to Exit.

Width Sonar Calibration (If equipped) - Follow

these instructions on-screen when calibrating the
WIDTH SONAR option

:

1. Move the outer edge of the offset arm gauge

flush with front of faceplate, hold at location and press
NEXT option

.

Note: It is highly important to position the gauge cor-

rectly as shown in figure 40.

Figure 40 - Offset Arm Gauge to Faceplate

2. Return offset arm to home position.

1

2

1

1

1

1

6

5

3

2

1

4

MENU

Gauge

Set to 6

Gauge

Set to 0

Shown with Recommended Settings

Advertising