• 27

Video Balancer

Error

Err. 12

Err.13

Err.14

Err.17

Err.18

Err.15 /

Err.16 /

Err.19

Err.20

Err. 30

Symptom

Error in the unbalance measur-

ing cycle.

Error in the unbalance measure-

ment.

Over ranging - too much unbal-

ance

Wheel stopped before it was

positioned or before taking

runout reading.

Clock error

Check

1. Press

and respin. Check PHASE in MACHINE SELF-TEST

“Green Screen”, if 180 deg diff., recalibrate & check piezos.

2. Check encoder adjustment and operation. (clearance .020” to .035”)

3. Check motor operation.

4. Check belt tightness.

5. Check hub nut tightness.

6. Replace the main PCB.

1. Press

and respin. Check PHASE, VCO (dynamic), VCI (static) in

MACHINE SELF-TEST “Green Screen”.

2. Check the piezo pick-ups connection. (electrical & mechanical)

3. Check the balancer spindle connections.

4. Mount a wheel having a known unbalance (lower than 3.5oz or 100

grams) and check the balancer readings.

5. Replace the PC board.

A.) Follow screen instructions for “heavy side” down balancing to bring

wheel unbalance into range and then balance normally.

B.) Follow instructions 1 thru 5 above.

1. Wheel too light - not enough inertia. Use heavier wheel.

2. Check positioning of sonar unit behind wheel.

1. Replace the PCB board.

EXIT

EXIT

Advertising