24 •

Important: Always read and follow the on-screen operating instructions.

Video Balancer

3. Pull out and position the calibration sonar target

bracket to front of faceplate.

4. Leave in position and close the hood.

Note: The target bracket, shown in calibration posi-

tion in figure 41, is used to allow the width sonar to
measure the distance to the balancer faceplate during
calibration.

Figure 41 - Sonar Target Bracket Positioned for Calibration

5. Screen indicates “Reading Value”.

6. Raise the hood and return the width sonar cali-

bration bracket to the stored position.

7. Calibration accepted.

Note: The sonar calibration target bracket is stored

flush with the side of cabinet at all other times, see fig-
ure 42.

Figure 42- Sonar Target Bracket in Stored Position

Diameter Arm Calibration - Follow these instruc-

tions on-screen when calibrating the DIAMETER ARM
option :

1. Mount a 14", 15", or 16" steel wheel with tire.

2. Using the + or -, set the diameter to the same

diameter as rim.

3. Press NEXT option

.

Note: The diameter will display on the screen.

4. Position offset arm at clip-on weight location on

wheel.

Figure 43 - Diameter Arm Calibration

5. Hold at location and press NEXT option

.

6. Screen indicates “Reading Value”.

7. Return offset arm to home position.

8. Calibration Accepted.

1

1

3

Sonar Target

Bracket

Sensor Target

Bracket in

Stored Position

Width

Sensor