Troubleshooting guide – Condux Gulfstream 200 Micro Fiber Blower User Manual
Page 18
18
Tractor Feed does not pull the cable off
the reel.
Blower cuts out with electronic error of
minspeed or highspeed error.
The cable run is hard to restart after
having stopped.
Tractor feed doesn’t start.
Assist the reel by pushing it, and/or by pulling
the cable off the reel.
Blower has exceeded the minimum or
maximum speed allowance. Adjust speed
accordingly, or wipe cable clean from mud
and dirt.
Put air to the system with the track down. The
tractor feed can be restarted after the air
pressure has increased and stabilized.
Tractor Drive switch is in the neutral "center"
position. Select forward or reverse.
Cable becomes jammed in the conduit
system.
1. Inform the people at the other end of
the conduit that a problem has been
experienced and the operator is going to
shut down the system.
2. Shut off the pneumatic air supply with the
Air Control Valve turning it to the 9 o’clock
position, allowing the air pressure to be
depressurized from the conduit and the
air block.
3. Using the counter or the measurement on
the cable, determine where the
blockage might be located.
4. Notify supervisor about problem and
determine a solution accordingly.
Problem
Solution
10.
Troubleshooting Guide