6. Close the Handheld Blower and secure (See Figure 16) Tighten speedball

handle securely, but do not over tighten.

7. Prove Conduit integrity and spread lubricant through Conduit.

a. Re-connect the air hose to the Handheld Blower and attach all

safety clips.


b. Open the air compressor air control valve.

c. Slowly

open

Air Control Valve by turning to the 6 o’clock

position. (See Figure 17)

d. Blow foam through conduit to spread lubricant and check for

blockage. Follow all safety precautions.

e. After the foam exits, close Air Control Valve by turning it to the 3

o’clock position.

Note: Foam must exit in a reasonable time, allow approximately 10
seconds per 1,000 feet (300 m) or conduit may be contaminated or
blocked.














8. Ensure

Handheld Blower is depressurized. Shut off the air from the

compressor, decompress the air in the hose and disconnect the hoses from
the handheld blower.

9. Remove

Seal Disk and install Ventrui (See Figure 18). Use the provided

2.5 mm hex wrench.


Note: The venturi with the groove
goes into the bottom and gets
screwed into place while the top
half has the protrusion and sets
into the groove.

Figure 16 close and tighten handle

Figure 17 Slowly open the air

control valve

Figure 18 Insert ventrui