Set up the handheld blower, Pressure test conduit – Condux Hand Held Micro Fiber Optic Blower User Manual

Page 5

Advertising
background image

5














































Set Up the Handheld Blower

Pressure Test Conduit:


The conduit system must be able to withstand a maximum pressure of 175 psi, and
be free of leaks. Conduit may be tested for pressure using the Handheld cable
blower, follow the steps below.

1. Loosen the speedball handle by turning it counter clockwise (Figure

1) until you are able to remove it from the bracket (Figure 2).















2. Select the correct Condux and Cable Components according to the

conduit and cable size. Refer to the Conduit and Cable Pack
selection charts (Table 1, 2, 3 & 4 on pages 17 & 18).

3. Choose the correct Conduit Seal and install both halves securely.

Use the provided 2.5 mm hex wrench (Figure 3).

4. Choose the correct Conduit Clamp and install both halves (same

color as the conduit seal). Used the provided 2.5 mm hex wrench
(Figure 4).

Figure 1 Loosen speedball handle

Figure 2 Remove speedball handle

from bracket

Figure 3 Install conduit seal

Figure 4 Install conduit clamp

Advertising