Troubleshooting Guide

3.

7.

PROBLEM:

CAUSE:

SOLUTION:

The diesel engine starter
doesn’t work.

Burned fuse

Replace

Ran down battery

Recharge or replace

Disconnected contacts of the
ignition system / starter

Reconnect

Oxidised contacts of the
ignition system / starter

Clean or spray with a
suitable vaporiser

Starter out of order

Replace / Technical
assistance

Diesel engine doesn’t
work.

The emergency push-
button is pushed in locked
position

Release

The ignition push-button is
not pushed

Push the ignition push-
button and keep it
pushed till the engine
starts

The pre-heating glow plugs
warning light isn’t turned off

Wait for the turning off
of the pre-heating glow
plugs warning light

Fuel problem

Check the fuel level in
the tank
Check the fuel filter

Diesel engine turns
off when releasing the
ignition push-button.

Check of the engine oil
pressure

Add engine oil
Defective sensor–
check contacts /
replace
Engine anomaly –
technical assistance

Check of the engine cooling
liquid temperature

Add cooling liquid
Defective sensor–
check contacts /
replace
Engine anomaly –
technical assistance

The feeding pressure
is lower than 24 bar
– 340psi

Clogged hydraulic oil filter

Replace

Defective pump

Technical assistance

Diesel engine doesn’t
increase rpm

Disconnected accelerator
cable

Verify and if necessary
replace