Condux WDR505 Underground Pulling Trailer User Manual

Page 20

Advertising
background image

20

PROBLEM:

CAUSE:

SOLUTION:

The machine doesn’t
reach the max. pull
performances.

Diesel engine rpm not
sufficient

Speed up the engine

Diesel engine decreases
rpm and turns off

Decrease the control
lever capacity

Excessive hydraulic oil
temperature

Wait for a few minutes
for cooling the oil. It
is possible to reduce
the oil cooling time
by turning on the
fan of the hydraulic
oil radiator and by
completely opening
the reel winder valve
with diesel engine at
medium-high rpm

Insufficient fuel feeding at
diesel engine

Check the fuel filter
Fuel feeding system
to be adjusted –
Technical service

The machine doesn’t
increase speed.

Diesel engine rpm not
sufficient

Speed up the engine

Diesel engine decreases
rpm and turns off

Decrease the control
lever capacity – the
applied pull doesn’t
allow to reach higher
speed

Excessive hydraulic oil
temperature

Wait for a few minutes
for cooling the oil. It
is possible to reduce
the oil cooling time
by turning on the
fan of the hydraulic
oil radiator and by
completely opening
the reel winder valve
with diesel engine at
medium-high rpm

Insufficient fuel feeding at
diesel engine

Check the fuel filter
Fuel feeding system
to be adjusted –
Technical service

Advertising