INSTALLATION OF HUMBBSFP1016-A--

FAN POWERED HUMIDIFIER

Bryant’s HUMBBSFP1016-A-- fan powered humidifier can only
be installed on the supply plenum of a forced-air system. This unit
requires an external 115-vac (fused) plug-in receptacle near the
equipment for proper operation.

It is recommended to install the humidifier where it can be easily
serviced. Pad access door can be easily converted from right to the
left hand side. Always install humidifier downstream of an
electronic air cleaner.

I.

INSPECT PACKAGE AND CHECK EQUIPMENT

Inspect contents of packaged humidifier. File claim with shipping
company prior to installation, if shipment is damaged or incom-
plete.

The package should contain:

1. Humidifier and media assembly

2. Humidistat

3. Template

4. Owner’s Manual

5. Warranty Certificate

6. Solenoid valve

7. Saddle valve assembly with adapter

8. Four sheet metal screws

9. Foam tape

10. Noise suppressor (use for water pressure over 60 psi)

11. Worm clamp for field-supplied drain tube

12. Humidifier maintenance instruction sticker

13. Bryant logo label

II.

SELECT LOCATION (SEE FIG. 7.)

Humidifier must be installed on supply plenum only. If furnace has
air conditioning coil, be sure humidifier does not interfere with coil
ends. Remember to provide clearance for maintenance and evapo-
rator pad removal.
To reverse pad access from right to the left side:

1. Remove side door and media pad assembly.

2. Remove 4 screws and separate top assembly from lower

mounting base. (See Fig. 8.)

3. Rotate lower mounting base 180 degrees, so side access

door is now on left.

4. Snap together top assembly to mounting base and reinstall

screws.

5. Replace media pad assembly (with distributor reservoir up)

and side access door.

CAUTION:

When re-installing media pad assembly into

plastic housing, insure the assembly drain stub aligns into
the drain outlet located in bottom of humidifier. Unit can
leak if drain stub does not align with drain outlet. (See
Fig. 9.)

IMPORTANT:

Make sure front housing assembly with electrical

cord is facing down.

III.

PREPARE PLENUM OPENING (SEE FIG. 2.)

1. Use template for marking humidifier opening.

2. Tape in place on plenum making sure template is level.

IMPORTANT:

For humidifier to operate properly it must be

level and mounted on a vertical surface.

3. Drill four 1/8-in. holes in plenum.

4. Cut opening in plenum using heavy solid lines on template

as a guide.

Fig. 7—Installation of HUMBBSFP1016-A--

Fan-Type Humidifier

A97098

VERTICAL

HORIZONTAL

HORIZONTAL

"N" COIL

Fig. 8—Reversing Door Access

on HUMBBSFP1016-A--

A96049

Fig. 9—Media Pad Assembly Installation

A97108

MEDIA PAD
ASSEMBLY

HOUSING
ENCLOSURE

DRAIN OUTLET

DRAIN
OUTLET

VINYL DRAIN
TUBING

—5—