Switch to heating or ventilation, 3 operation and setting/adjustment – Eberspacher EasyStart Remote User Manual

Page 12

Advertising
background image

12 | VehiCLe heATeRs – TeChniCAL DOCuMenTATiOn

3 OpeRATiOn AnD seTTing/ADjusTMenT

switch tO heating Or VentilatiOn

please nOte!

This function is only possible if the heater
supports the VenTiLATiOn function.
A switched on heater is switched off with this
setting.

keep the

button pressed until “CuRRenT

OpeRATing TiMe is DispLAyeD” appears.

Data transmission

LeD: lights up green

LeD: flashes red for
8 seconds

Data transmission

LeD: lights up green

The current operat-
ing time is indicated
by flashing.

Release the

button while the operating

time is flashing.

please nOte!

Make the following setting within 30 seconds
of letting go of the

button.

press the

button again; the operating

mode is changed.

ƒ

switch from heATing to VenTiLATiOn

LeD: flickers green
for approx. 10
seconds

ƒ

switch from VenTiLATiOn to heATing

LeD: flickers red for
approx. 10 seconds

please nOte!

The operating mode is permanent until it is
changed over again.

The setting can be exited with a timeout.