Ds gb f, The following 3 operating modes are available – Eberspacher Calltronic 01 User Manual

Page 3

Advertising
background image

3

D

S

GB

F

Operating the heater via the numeric
keys on the telephone

You first have to set up a connection between the
telephone and the

CALLTRONIC

.

To do this, dial the

number assigned to you by

your network operator.

The

CALLTRONIC

signals the following text:

“Eberspächer heater – Input PIN“.

Now enter the 4-digit PIN No.
(The PIN is set to 0000 in the works).

The following 3 operating modes
are available

Note:

If malfunctions occur in the heater during operation
(e.g. due to a lack of fuel), these can be interro-
gated after the malfunction has occurred using
Function 6 (where the diagnosis cable is connected).
The malfunction is corrected with the aid of the
operating instructions for the heater.

1. Stand-alone operation

The function keys 0 to 7 are active at the telephone
(see the following table).
The push-button installed can be used to switch the
heater on or off. If the heater is switched on using
the push-button, the heating function is activated
with a duration of 40 mins. The push-button also
functions without a SIM card. The push-button
flashes if an error occurs in the heater.

2. Combination with mini clock

The function keys 0 to 3 and 5 to 7 are active (see
following table).
The functions of the function key 4 (Select operating
mode) are taken over by the mini clock (see installa-
tion and operating instructions for the mini clock).
When switching on the heater via the mini clock, the
operating mode last set with the mobile phone is
always activated. If a malfunction occurs in the
heater, the reading in the mini clock display changes
between the time and “--“.
If the

CALLTRONIC

is connected with the mobile

phone, “--“ appears in the mini-clock display.

3. Combination with

mini controller

When combined with the

CALLTRONIC

, the mini

controller only serves to specify the set value.
Select heating mode at the mini controller. The red
LED in the mini controller only serves as an operat-
ing display – not as an operating mode display – the
operating mode is selected via the remote control.

If the PIN No. is wrong, the following message
appears:

“PIN invalid“.

You now have the opportunity to enter the correct
PIN No.

If the PIN No. is correct, the following message
appears:

“PIN OK – Input command“.

You can now enter your settings for the heater via
the

CALLTRONIC

.

The following table on Pages 4 and 5 shows which
functions are available to you.