• Remove the remaining actuator assembly from the integral valve

body (see Figure 13)

Figure 13


The following steps outline how to install a valve lever actuator.

• Install the actuator adapter sub assembly to the valve. Ensure the

valve ball is in the closed position (see Figure 13)

• Install the socket head cap screws that attach the actuator

assembly to the integral valve body use Loctite® #242 thread lock
or equivalent. (see Figure 13)

Socket Head Cap Screw