Elkhart Brass Scorpion RF 8394-07 User Manual

Page 5

Advertising
background image

5

SYSTEM COMPONENTS

MONITOR
Scorpion RF Monitors – 8294-06 & 8394-07
The 8294-06 and 8294-06 EXT is a cast aluminum monitor with 4”

waterway while the 8394-07 is cast brass. The waterway contains a

central vane to minimize large-scale turbulence and provide superior

fire streams. Monitor water supply connection is a 4 inch 150 lb. ANSI

pattern flange. The discharge nozzle connection is 3½” National Hose

thread. Nozzle stream direction is controlled by two permanent magnet

type planetary gear motors, one controlling rotation about the axis of

the water inlet, and the other controlling nozzle elevation and

depression. Right angle gear cases between the gear motor and the

monitor allow for convenient manual override of the electric motors in

the event of a power failure during firefighting operations. All gearing

is enclosed within the monitor housings.

Scorpion RF Monitor – 8294-06 EXT
The extended travel Scorpion has the same highly efficient waterway

and flow capacity as the Scorpion RF monitor. The monitor waterway is

supplied through a 4” 150# flat faced flange base. The 8294-06 EXT

monitor has a mechanical stop to allow 180° for added protection in an

aerial application.

The extended travel Scorpion RF has special features to

optimize performance as an aerial master stream

device when used on a straight aerial ladder with

pinnable waterway. The pinnable waterway feature

allows the waterway to be pinned to the second fly

section of the ladder (egress position), thus keeping the

monitor and nozzle away from the end fly section when

it is necessary to place the ladder tip at a window sill or

roof parapet.

The 8294-06 EXT contains a special wiring harness connection at the inlet flange to allow attachment

of an OEM provided proximity sensor. The proximity sensor is used to tell the monitor controller which

positions the waterway and monitor is. As a result, the monitor discharge Up-Down travel range differs

for the two waterway and monitor positions as indicated in Table 1.

Waterway/Monitor Position

Up-Down Travel Range

Master Stream

+30° to -135°

Egress

+0° to -135°

Table 1: EXT Travel Ranges

The 0° position is when the nozzle is aimed parallel to the ladder.

As a further enhancement, the left-right motor direction of rotation automatically reverses when the

monitor discharge is in the range of 0° to +30°. Without this feature, when the discharge travels

above 0°, “left” would functionally become “right” and vice versa.

Advertising
This manual is related to the following products: