Elkhart Brass UBEC 1AT AUTO TANK Fill System User Manual
Page 10
10
Control Valve
Installation instructions for the control valve can be found in the Unibody Valve and Controller Manual
(Document P/N 98311000). After installing the control valve, connect the AUTO TANK Control Module
to the control valve using the supplied harness. Please see Wiring section on page 18.
Note: Be sure to perform an automatic position calibration on the control valve after installation. This
procedure can be found on page 13.
Note: The AUTO TANK Fill Controller is intended to be used only with Elkhart Unibody control valves
that utilize an E3F electric actuator. Do no attempt to use with any other control valve, doing so could
result in damage to the Controller and will void the warranty.