Powering up, Initializing the system, Heat dissipation – ElmoMC SimplIQ Digital Servo Drives-Guitar Installation Guide User Manual

Page 54: Guitar thermal data

Advertising
background image

Guitar Installation Guide

Installation

MAN-GUIIG (Ver. 1.601)

www.elmomc.com

54

3.13. Powering Up

After the Guitar is connected to its device, it is ready to be powered up.

Caution: Before applying power, ensure that the DC supply is within the
specified range and that the proper plus-minus connections are in order.

3.14. Initializing the System

After the Guitar has been connected and mounted, the system must be set up and initialized.
This is accomplished using the Composer, Elmo’s Windows-based software application. Install
the application and then perform setup and initialization according to the directions in the
Composer Software Manual.

3.15. Heat Dissipation

The best way to dissipate heat from the Guitar is to mount it so that its heatsink faces up. For
best results leave approximately 10 mm of space between the Guitar's heatsink and any other
assembly.

3.15.1. Guitar Thermal Data

Heat dissipation capability (θ): Approximately 8 °C/W.

Thermal time constant: Approximately 360 seconds (thermal time constant means that the

Guitar will reach 2/3 of its final temperature after 6 minutes).

Shut-off temperature: 86 °C to 88 °C (measured on the heatsink)