Show Control Setup

7

Port Setup Options

Eos Ti, Gio, Ion, and Element have additional ports and connectors located on the rear panel for
show control. Additional setup options for these ports and connectors are in the
ECU>{Settings}>{Local I/O}.

Group IDs

Allows you to set the group number for the MIDI In and MIDI Out ports. Group numbers can be from
1-32. Default for both ports is 1.

Contact Closure (remote trigger connector)

Allows you to set the Group and Address In values for the remote trigger input on the back of your
console. The contact closure only reports on/off even though it is considered an analog input.

Relay Out (remote trigger connector)

Allows you to set the Group and Address In values for the remote trigger port on the back of your
console.

N o t e :

The local ports on Eos Ti, Gio, Ion, and Element consoles will not broadcast

information over the network and are only used in a local console system.

N o t e :

The contact closures require DC voltage, which is supplied by the console on pins

14+15. See the diagram below.

1

2

3

4

5

6

7

8

15

14

13

12

11

10

9

Ground

Ground

+ 12Vdc

+ 12Vdc

S1

S2

S3

S4

Relay Out, Normally Closed

Relay Out, Normally Open

Relay Out, Common

8 7 6 5 4 3 2 1

15 14 13 12 11 10 9

Remote Trigger

connector pinout