Setup, Led indicators, Initial setup – EUCHNER CES-AR-C01-CH-SA (Multicode) User Manual

Page 20: Functional check, Setup 20 led indicators

Advertising
background image

Operating Instructions Safety Switch CES-AR-C01-CH-SA

20

Setup

LED indicators

LED

Color

State

Significance

STATE

green

illumi-

nated

Normal operation

flashing

- Teach-in operation or Power Up

- Actuator in limit range (V. 1.1.2 or higher)

(refer to the status table for further signal functions)

DIA

red

illumi-

nated

- Internal electronics fault

- Fault at the inputs/outputs

Initial setup

1. Apply operating voltage to the safety switch.

¨

The green LED flashes quickly (approx. 10 Hz)

A self-test is performed during this time (approx. 8 s). After this, the LED

flashes cyclically one time and signals that it is in standby state.

2. Move actuator to the read head (observe distance < S

ao

).

¨

The green LED illuminates continuously and indicates the detection of the

actuator.

Functional check

After installation and any fault, the safety function must be fully checked. Proceed

as follows:

Warning!

Danger of fatal injury as a result of faults in installation and functional check.

Ì

Before carrying out the functional check, make sure that there are no per-
sons in the danger area.

Ì

Observe the valid accident prevention regulations.

1. Switch on operating voltage.

Ì

The safety switch carries out a self-test.

The green LED STATE flashes for 8 s with 10 Hz.

The STATE LED then flashes at regular intervals.

2. Close all safety guards.

Ì

The machine must not start automatically.

Ì

The green STATE LED illuminates continuously.

3. Enable operation in the control system.
4. Open the safety guard.

Ì

The machine must switch off and it must not be possible to start it as long as

the safety guard is open.

Ì

The green LED STATE flashes at regular intervals.

Repeat steps 2-4 for each safety guard.

Advertising