Operating Instructions Safety Switch CES-AR-C01-CH-SA

21

System status table

Operating mode

Actuator/door posi

-

tion

Safety outputs OA and OB

LED indicator,

output

State

ST

ATE (gr

een)

DIA (r

ed)

Self-test

X

off

10 Hz

(8 s)

Self-test after power up

Normal operation

closed

on

Normal operation, door closed

closed

on

flashes

quickly

2 Hz

Normal operation, door closed, actuator in limit range

¨

Re-adjust door (V. 1.1.2 or higher)

closed

off

1 x in-

verse

Normal operation, door closed, preceding device in the switch chain signals "door open" (only with

series connection)

open

off

1 x

Normal operation, door open

Fault display

X

off

2 x

Input fault (e.g. missing test pulses, illogical switch state from previous switch in the switch chain)

closed

off

3 x

Defective actuator (e.g. fault in code or code not readable)

X

off

4 x

Output error

(e.g. short circuits, loss of switching ability)

X

off

5 x

Internal fault (e.g. component faulty, data error)

X

off

X

X

Internal fault with door fault

Key to symbols

LED not illuminated

LED illuminated

10 Hz (8 s)

LED flashes for 8 seconds at 10 Hz

3 x

LED flashes three times, and this is then repeated

X

Any state

After the cause has been remedied, faults can generally be reset by opening and

closing the door. If the fault is still displayed afterward, use the reset function or

briefly interrupt the power supply. Please contact the manufacturer if the fault could

not be reset after restarting.

Important!

If you do not find the displayed device status in the System status table, this indi-
cates an internal device fault. In this case, you should contact the manufacturer.