8.0

Operation

8.1

VX700 Control Features, (Continued)


8.1.4

Fan


2. Stator

The Stator is attached to the backside of the front finger guard. The purpose
of the Stator is to convert the radial dispersion of air to a narrow axial beam
of air. The stator creates a PowerStream™ of air that allows the VX700 to
be setback 8 to 30 feet from the doorway of a building being exhausted of
smoke without losing fan efficiency.


The greater setback distance un-clutters the entrance of the build to allow
plenty of room for firefighters and equipment to move in and out of the
building without tripping over a PPV fan.


3. Misting Ring


The VX700 is equipped with an 8 nozzle Misting Ring built into the shroud
cover of the fan. The standard issue nozzle provide 1.5 gallons of water per
minute at a water supply pressure of 200psi. Other nozzle options are
available to supply a mist flow rate up to 10 gallons per minute.



8.2

Run Procedure

8.2.1

Start-Up


1. Read the VX700 Owner's Manual completely before starting fan.


2. Wear both eye and ear protection.


3. Do checks as indicated in Preparation for Use, section described above.


4. Position the VX700 Fan on a level surface.

Note: Oil Alert feature will shut the motor down if engine is tip or leaning in
excess of 20 degrees.


5. Position optional trailer or other vehicle the VX700 is mounted to for the

desired set-back distance, typically between 20 to 30 feet for the VX700.


6. Position optional trailer or other vehicle to point the VX700 Fan in the desired

direction towards the opening in a building.


7. Set hand brake on optional trailer or vehicle to prevent fan from moving

during operation.


8. Attach the water supply hose if the mister feature is to be used.


Note: The pressure of the water source must be restricted to a maximum of
125 psi.