Brita 1200 User Manual

Page 10

Advertising
background image

6.1 Removing the Filter Cartridge

Switch off the power supply of the terminal equipment (remove plug).
Close the inlet valve

6

at the inlet hose

5

.

Place the fl ush hose in a bucket and remove pressure from the fi lter system by
opening the fl ush valve

16

. Collect waste water in the 10L bucket.

Note: If the escaping water is more than 1 litre, the inlet value

6

is not completely

closed or is blocked with scale.

Stand on the kick loops

9

with both feet while opening the pressure

vessel lid

3

by pressing the lock

8

and turning it anti-clockwise as

far as it will go. The fi lter cartridge

2

is released by pressing on the

mantle handles

11

.

Place the pressure vessel lid

3

vertically on the lid handle

14

.

Stand on the kick loops

9

with both feet while turning the pressure

vessel

1

anti-clockwise by the mantle handles

11

as far as it will go.

Take your feet off the kick loops

9

and press the pressure vessel

1

down with both hands on the mantle handles

11

.

Remove used fi lter cartridge

2

from the pressure vessel

1

.

Place the used fi lter cartridge

2

in the sink with the connection facing down for

drainage (> 5 min).
Lock the used fi lter cartridge

2

with the transport protection cap

12

of the new fi lter

cartridge and return in the original packaging to the appropriate BRITA address listed
on the back of the cover.

6.2 Inserting the Filter Cartridge

Check the O-ring seal of the new fi lter cartridge

2

for correct seat in the groove, dirt

and damage. Note: The cartridge seat has been lubricated with food-safe lubricant at
the factory.

Check the connector seat of the fi lter cartridge O-ring

2

in the pres-

sure vessel lid

3

for dirt and damage.

Place new fi lter cartridge

2

in the pressure vessel

1

.

Stand on the kick loops

9

with both feet; lift the pressure vessel

1

whole turning clockwise until the mantle handles

11

are over the kick

loops

9

.

Stand on the kick loop

9

with both feet and place the pressure vessel

lid

3

on the pressure vessel

1

. The positioning of the arrow marking

on the lid handle

14

must line up with the “INSERT” groove.

Press the pressure vessel lid

3

down and turn clockwise until the

lock engages

8

.

Switch on electrical power supply to the terminal device.
Execute the steps described under 5.3 to fl ush and bleed the new
fi lter cartridge

2

.







18